Hardware operations
This guide collects hardware maintenance procedures and hardware issues we diagnosed, so we don't have to rediscover them.
BMC management with IPMI
The pve2 node (Supermicro X10SRL-F motherboard) has a BMC reachable at
10.246.67.56. Query and configure it with ipmitool over the LAN interface:
ipmitool -I lanplus -H 10.246.67.56 -U ADMIN sensor list
Configure fan thresholds
Quiet, low-RPM fans can dip below the factory lower thresholds, triggering false critical events and BMC fan-boost cycling. Lower the thresholds of the affected fan sensors to stop that:
ipmitool -I lanplus -H 10.246.67.56 -U ADMIN sensor thresh FAN1 lower 150 200 250
ipmitool -I lanplus -H 10.246.67.56 -U ADMIN sensor thresh FAN2 lower 150 200 250
The three values after lower are, in order: lower non-recoverable, lower
critical, and lower non-critical.
Thresholds are stored in the BMC, so they may need re-applying after a BMC firmware update or a BMC factory reset.
The BMC address is a DHCP lease, so it can change. The bootstrap role also
installs ipmitool on the host itself for hosts flagged has_bmc in their
host_vars: in-band commands (ipmitool sdr type Fan, ipmitool sensor) work
over SSH regardless of the BMC's address, through the /dev/ipmi0 interface the
kernel exposes. On 2026-10-04 the fan mode read Optimal, the fans 300-1100 RPM,
and FAN1 sat below its lower non-critical threshold at 300 RPM, the symptom the
thresholds above address.
BIOS configuration with SUM
Supermicro Update Manager (SUM) reads and writes the BIOS configuration as a text file. On this board generation it is the only programmatic path: the BMC's Redfish 1.0.1 service has no BIOS resource, and IPMI does not expose settings.
- The tool is proprietary and stays out of the repository: keep the downloaded archive outside the working tree (the control machine's downloads directory) and copy the extracted directory to the host only for the duration of a command, then remove it.
- In-band use needs no license and no driver on Linux unless Secure Boot is enabled (disabled on pve2). Out-of-band use through the BMC requires Supermicro's per-node activation key, which X10 boards do not include.
-
Export the current configuration, as root on the host:
./sum -c GetCurrentBiosCfg --file pve2-bios-current.cfg --overwrite -
Apply changes from a compact file holding only the changed settings:
./sum -c ChangeBiosCfg --file pve2-bios-changes.cfgThe uploaded configuration takes effect only after a reboot or power-up;
--rebootrestarts the host right away. Verify from the OS after the boot (SATA capability bits and port flags, memory speed, controllers present inlspci), then measure on the plug. The compact file is the declared BIOS state and belongs in the repository once applied (pve2's isconfig/bios/pve2/bios-changes.cfg); the full export does not. An export taken right afterChangeBiosCfgstill shows the old values: the change is staged and only visible after the reboot.
Supermicro X10SRL-F motherboard standoff short
The Supermicro X10SRL-F motherboard doesn't have the standard ATX mounting hole layout. In a case with standoffs installed for the standard layout, one standoff has no matching hole and shorts the C1/C2 DIMM slot solder contacts on the underside of the board. Removing that standoff fixed the issue, with no permanent damage in our case.
When mounting a motherboard, verify that every installed case standoff aligns with a motherboard mounting hole, and remove the unmatched ones.